NINGBO CRRCTIMES TRANSDUCER TECHNOLOGY CO.,LTD.
|
Payment Terms: | T/T |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
For the electronic measurement of currents: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high power) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal current IPN: 1000A r.m.s
2. Primary current, measuring range IP: 0~±2000A
3. Secondary normal current:200mA rms
4. Conversion ratio: 1:5000
5. Supply voltage(1±10%): ±15V~±24V
1. @±1000A max 0Ω~15Ω ±15V @±1200A max 0Ω~4Ω ±15V @±1000A max 0Ω~50Ω ±24V @±1200A max 0Ω~5Ω ±24V |
6. Current consumption: ≤35mA(+ Secondary output current
7. Isolation test: Between the primary circuit to the secondary circuit(+.-.M): 7kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy @ IPN, TA=+25 oC, ≤±0.4%
2. Non-linearity: better than 0.1%, TA=+25 oC
3. Offset current @ IP=0, TA=+25 oC: not more than ±0.4mA
4. Thermal drift: ±0.8mA(-40 oC ~-85 oC)
±0.7mA(-25 oC+70oC)
5. Reaction time @10% of IP max : less than 500ns
6. Response time @90% of IPN: not more than 1us
General data:
1. Operating temperature: -40℃~+85℃
2. Storage temperature: -40℃~+90℃
3. Secondary coil resistance: not more than 45Ω(@+25℃)
4. Weight:
1.02kg
1.68kg
5. Standards: EN 50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PC recognized according to UL 94-V0
4. The whole current transducer comply with RoHS Directive completely
1000A Excavator transducer Dimension:
1000A Excavator transducer Connection: