NINGBO CRRCTIMES TRANSDUCER TECHNOLOGY CO.,LTD.
|
Payment Terms: | T/T |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
NCV4 Series Voltage Transducer
Applications:
Applicable to isolated precise measurement of DC voltages.
Main technical data:
1. Primary voltage Primary resistance type
measuring range VPmax(V) @ TA=+25 oC (kilohm)
+100 100 NCV4-100V
+200 200 NCV4-200V
+400 400 NCV4-400V
+500 500 NCV4-500V
+1000 1000 NCV4-1000V
2. Output current: +4mA~+20mA
3. Supply voltage (+/-10%) Vc: +24V
4. Current consumption: ≤60mA+ Secondary output current
5. R.m.s. voltage for DC isolation test 1.5kV DC/1min
6. Loading resistance: ≤500Ω
Accuracy – Dynamic performance data:
1. Accuracy @VPN, TA=-25 oC ~+70oC: +/-1%
2. Non-linearity @ VPN, TA=+25 oC: +/-0.1%
3. Thermal drift of the gain (% of reading): ±0.04mA(-25ºC~+70ºC)
4. Response time (@ 90% of VPmax): ≤300ms
5. Offset current: 4mA±0.02mA(+25ºC )
General data:
1. Operating temperature: -25 oC ~+70 oC
2. Storage temperature: -40 oC ~+85oC
3. Weight: 80g
4. Standards: EN50155
Features:
1. Close loop (compensated) voltage transducer
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PC recognized according to UL 94-V0
Dimension:
Connection: