Model No.: NV25-400V
Production Capacity: 10000 Piece/Pieces per Mont...
Delivery Date: 15 --20 days
Theory: Hall Sensor
Primary normal voltage: 400V
Means of Transport: Ocean
Packing: According to customer's req...
Output: Switching Transducer
Usage: Level Sensor

For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the
primary (high voltage) and the secondary (electr

Applications:                                             
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the
primary (high voltage) and the secondary (electronic) circuits.

Main technical data:
1. Primary normal voltage VPN: 400V r.m.s
2. Measuring resistance:               RMmin    RMmax
with +/-12V   @±VN max :    30 ohm    200 ohm
                       @±1.5×VN:     30 ohm    100 ohm
with +/-15V   @±VNmax:      100 ohm   320 ohm
                       @±1.5×VN:     100 ohm   180 ohm
3. Primary voltage, measuring range VP: 0~+/-600V
4. Secondary nominal output: 25mA rms
5. Conversion ratio: 2500:1000
6. Supply voltage(+/-5%): +/-12V~+/-15V                        
7. Current consumption (@±15V):10mA + Secondary output current
8. Isolation test: Between the primary circuit and the secondary circuit: 4.1kVrms/50Hz/1min

Accuracy – Dynamic performance data:
1. Accuracy @ VPN, TA=+25 C: +/-0.8%
2. Non-linearity @ VPN, TA=+25 C: +/-0.2%
3. Offset current ≤±0.15mA(@+25℃)
4. Thermal drift:   +/-0.60mA(-25 C ~+25 C)
+/-0.35mA(-25 C ~+70 C)
5. Response time: not more than 15us

General data:
1. Operating temperature: -25oC~+70oC
2. Storage temperature: -40 C ~+85 C
3. Primary resistance : 40kilohm
4. Secondary coil resistance: not more than 110 ohm
5. Weight: 70g×(1±20%)g
6. Standards: EN50155

Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit

Dimension:
NV25-400V Voltage Transducer

Connection:
NV25-400V Voltage Transducer




 

bigPhoto
 Ms. LIANG

Tel: 86-574-87354108
Fax: 86-574-87359851
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

NINGBO CRRCTIMES TRANSDUCER TECHNOLOGY CO.,LTD. [China (Mainland)]


Business Type:Manufacturer, Trading Company, Agent, Distributor/Wholesaler
City: Ningbo
Province/State: Zhejiang
Country/Region: China (Mainland)

You May Like: