NINGBO CRRCTIMES TRANSDUCER TECHNOLOGY CO.,LTD.
|
Payment Terms: | T/T |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
NCV1-2250/SP3 Voltage Transducer
Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal voltage VPN: 1500V r.m.s
2. Primary voltage, measuring range VP: 0~+/-2250V
3. Conversion ratio: 1500V/50mA
4. Secondary nominal output: 50mA r.m.s
5. Measuring resistance: RMmin RMmax
with +/-15V~+/-24V @ +/-1500V max: 0 ohm 100 ohm
@ +/-2250V max: 50 ohm 100 ohm
6. Supply voltage(+/-5%): +/-15V~+/-24V
7. Current consumption: ≤45mA(@±24V)+ Secondary output current
8. Isolation test: Between the primary circuit and the secondary circuit(+.-.M): 7kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy @ VPN, TA=+25 oC: +/-1%
-40 oC~+85 oC: +/-3%
2. Non-linearity @ VPN, TA=+25 oC: better than +/-0.1%
3. Offset voltage @ VP=0, TA=+25 oC: not more than +/-0.25mA
@ VP=0,TA=-40 oC~+85 oC: not more than +/-0.75mA
4. Response time @90% of VP max:≤4us
5. Frequency bandwidth (-3dB): DC 15kHz
General data:
1. Operating temperature: -40ºC~+85ºC
2. Storage temperature: -45 oC ~+90 oC
3. Total primary power loss: 2W
4. Primary resistance @ TA=+25 oC: 1125 kΩ
5. Weight: ≤420g
6. Standards: EN 50155
Features:
1. Close loop (compensated) voltage transducer
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PC recognized according to UL 94-V0
Dimension:
Connection: