NVCL.1000B-11 Voltage Transducer
Payment Terms: |
T/T |
Place of Origin: |
Zhejiang, China (Mainland) |
Product Detail
Model No.:
NV200-1000V (TQG3)
Production Capacity:
10000 Piece/Pieces per Mont...
Delivery Date:
15 --20 days
Theory:
Hall Sensor
Primary normal voltage:
1600V
Means of Transport:
Ocean
Packing:
According to customer's req...
Output:
Switching Transducer
Usage:
Level Sensor
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PPO reco
Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the
primary (high voltage) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal voltage VPN: 1000V r.m.s
2. Primary voltage, measuring range IP: 0~+/-1500V
3. Secondary normal current: 80mA rms
4. Supply voltage (+/-10%): +/-15V~+/-24V
5. Current consumption: (35±5)mA + Secondary output current
6. Isolation test: Between the primary circuit and
the secondary circuit and shield (+.-.M.E): 6kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy @ VPN: ±1%(-25oC~+70oC)
2. Non-linearity @ VPN: ±0.1%(20℃±5℃)
3. Offset current: ≤±0.5mA
4. Response time @90% of VPmax: 70us
General data:
1. Operating temperature: -25oC~+70oC
2. Storage temperature: -40 oC ~+85oC
3. Weight: 3kg
4. Standards: EN 50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of black PPO recognized according to UL 94-V0
Dimension:
![NV200-1000V (TQG3) Voltage Transducer](http://img.hisupplier.com/var/userImages/2012-11%2F15%2F162517616475.jpg)
Connection:
![NV200-1000V (TQG3) Voltage Transducer](http://img.hisupplier.com/var/userImages/2012-11%2F15%2F162530611192.jpg)
Related Search