1. Primary normal voltage VPN: 200V r.m.s
2. Primary voltage, measuring range VP: 0~+/-300V
3. Conversion ratio: 200V/50mA

NV25-100V Voltage Transducer

Applications:                                            

For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits.

Main technical data:

1. Primary normal voltage VPN: 100V r.m.s

2. Measuring resistance:               RMmin    RMmax

with +/-12V   @±VN max :   30 ohm    200 ohm

                        @±1.5×VN:    30 ohm    100 ohm

with +/-15V   @±VNmax:     100 ohm   320 ohm

                        @±1.5×VN:    100 ohm   180 ohm

3. Primary voltage, measuring range VP: 0~+/-150V

4. Secondary nominal output: 25mA rms

5. Conversion ratio: 2500:1000

6. Supply voltage(+/-5%): +/-12V~+/-15V                       

7. Current consumption (@±15V):10mA + Secondary output current

8. Isolation test: Between the primary circuit and the secondary circuit: 4.1kVrms/50Hz/1min

Accuracy – Dynamic performance data:

1. Accuracy @ VPN, TA=+25 oC: +/-0.8%

2. Non-linearity @ VPN, TA=+25 oC: +/-0.2%

3. Offset current ≤±0.15mA(@+25℃)

4. Thermal drift: +/-0.6mA(-25oC ~+25 oC)

+/-0.35mA(-25oC ~+70 oC)

5. Response time: not more than 15us

General data:

1. Operating temperature: -25ºC~+70ºC

2. Storage temperature: -40 oC ~+85 oC

3. Primary resistance : 10kilohm

4. Secondary coil resistance: not more than 110 ohm

5. Weight: 70g×(1±20%)g

6. Standards: EN50155

Features:

1. Hall effect measuring principle

2. Galvanic isolation between primary and secondary circuit

Dimension:

Connection:
NV25-100V Voltage Transducer

bigPhoto
 Ms. LIANG

Tel: 86-574-87354108
Fax: 86-574-87359851
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

NINGBO CRRCTIMES TRANSDUCER TECHNOLOGY CO.,LTD. [China (Mainland)]


Business Type:Manufacturer, Trading Company, Agent, Distributor/Wholesaler
City: Ningbo
Province/State: Zhejiang
Country/Region: China (Mainland)

You May Like: