NINGBO CRRCTIMES TRANSDUCER TECHNOLOGY CO.,LTD.
|
Payment Terms: | T/T |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
NV25-200V Voltage Transducer
Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits.
Main technical data:
1. Primary normal voltage VPN: 200V r.m.s
2. Measuring resistance: RMmin RMmax
with +/-12V @±VN max : 30 ohm 200 ohm
@±1.5×VN: 30 ohm 100 ohm
with +/-15V @±VNmax: 100 ohm 320 ohm
@±1.5×VN: 100 ohm 180 ohm
3. Primary voltage, measuring range VP: 0~+/-300V
4. Secondary nominal output: 25mA rms
5. Conversion ratio: 2500:1000
6. Supply voltage(+/-5%): +/-12V~+/-15V
7. Current consumption (@±15V):10mA + Secondary output current
8. Isolation test: Between the primary circuit and the secondary circuit: 4.1kVrms/50Hz/1min
Accuracy – Dynamic performance data:
1. Accuracy @ VPN, TA=+25 oC: +/-0.8%
2. Non-linearity @ VPN, TA=+25 oC: +/-0.2%
3. Offset current ≤±0.15mA(@+25℃)
4. Thermal drift: +/-0.6mA(-25oC ~+25 oC)
+/-0.35mA(-25oC ~+70 oC)
5. Response time: not more than 15us
General data:
1. Operating temperature: -25ºC~+70ºC
2. Storage temperature: -40 oC ~+85 oC
3. Primary resistance : 20kilohm
4. Secondary coil resistance: not more than 110 ohm
5. Weight: 70g×(1±20%)g
6. Standards: EN50155
Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
Dimension:
Connection: