NINGBO CRRCTIMES TRANSDUCER TECHNOLOGY CO.,LTD.
|
Payment Terms: | T/T |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Summary
NYP1B pressure gauge is a kind of 240° wide angle gauge, which connects matched sensor, measuring pressure signal of running locomotive. The gauge is composed of measuring mechanism, measuring circuits, lighting circuits, and shell etc.. It is endowed with following advantages: small volume, convenient installation, good shock-proof, and good reliability. It is applicable to various locomotives at home and abroad.
Technique Parameter
1\Accuracy:±1.5%;
2\Inner lighting:LED light 24VDC
3\Applicable environment:-25℃~+50℃,Relative humidity ≤95%
4\Insulation strength: 1000V/50Hz/1min sine wave
5\Vibration:comply to Grade 1 Class B(TB/T3058)
6\Protection grade:Front plate IP54,Connector IP40;
7\Weight:≤0.8Kg;
8\Connector:DB 9-pin connector;
Outline Dimension
Connection Diagram
Installation & Operation
1\Clip-hoop support helps installation, opening hole dimension of gauge head Φ101mm
2\When using, observe the primary nominal value and lighting voltage, which should be in accord with the order.
3\Wiring connection refers to connection diagram. Make sure correct connection. (If connect lighting with signal input terminal, the gauge head would be damaged.) Pay attention to the polarity of gauge pointer and lighting. Connect cable shield layer with the gauge shell grounding.
Checkout & Maintenance
1\To adjust the linearity, take off the rubber plug at the bottom of gauge, then use screwdriver to adjust the potentiometer, making linearity reach the stipulated value.
2\The gauge has to be returned to manufacturer for maintenance, if pointer "zero" point changing, pointer deviation error, and lighting malfunction happen. Don't open the gauge before manufacturer's maintenance.
3\In the process of operation, make sure avoiding frequent and longtime overload.